Stabilant 22 Contact Enhancer Application Notes

App. Note 29 - Outdoor Environments

What are some of the environmental conditions that cause connector failure?

Typically, these are those found in coastal regions where a combination of salt-spray and high winds combine with fog, rain, and large temperature variations to produce an environment which is very hard on electrical connectors.

What are some of the reasons for connector failure under these conditions?

There are two areas of failure, physical failure of the connector, and electrical failure of the connector. While there are some designs in which only one or the other failures will occur, normally a combination of failures will take place.

PHYSICAL FAILURES:

The physical failures generally result from the use of connectors which are not designed for the environmental conditions encountered. Unfortunately even with all the thousands of designs on the market today, it is often very difficult to find a connector which will survive some severe environments, and when one is found, the limited market for such a design usually results in very high costs. The engineer specifying the connector has to face the decision of first cost vs. replacement/maintenance costs and it is not unusual for the initial cost of the connector coupled with an apparently low replacement cost to account for the choice of connectors. Bu sometimes environmental effect costs due to increasing pollution levels are underestimated in the same way that long term maintenance costs due to rising labor costs are underestimated.

The most common physical failure results from corrosion eating away the parts of the connector holding the male and female components together. The result is that the connector simply disconnects. The cause of the corrosion is usually a lack o resistance of the connector body material and/or finish to the combination of salt/water and/or chemicals in the environment. The corrosion can be hastened by the use of materials which are incomparable galvanically, or by the use of the connector shell as both a physical coupling and a current carrying element.

Assuming that the connector cannot be replaced with a type more suitable for the climate, and that the connector is still functioning, the usual solution is to clean all traces of salt/corrosion from the connector, and re-assemble it, finishing by enclosing it in such a way as to prevent the entry of the contaminants. This may consist o "buttering" over the connector body with a high viscosity silicon grease and enclosing it in some sort of protective sleeve which will prevent the grease from being eroded away.

A second vulnerable area is the connection between the wire or cable and the connector itself. Many physical failures take place because salt water has penetrated into that part of the connector where the wires are crimped or soldered onto the pins. Quite apart from the electrical effects of the corrosion products, these products frequently occupy much more volume than the metal upon which they feed. Occasionally enough pressure can be generated to rupture a shell that has already been weakened by corrosion.

Sometimes it is necessary to use a supplementary means of cable/wire strain relief in order to minimize the effects of wind-induced vibrations in the cable in causing a "grinding" action between the two halves of the connector.

A third type of failure is the exposure of the connector to unusual corrosive liquids or gasses not normally encountered in the environment but which might be generated, from time to time, by other failures in the operating plant. This can also extend to corrosion-inducing chemicals being liberated from connector components subject to over-heating due to thermal runaway of contact-wire junctions.

This latter also suggests that we must also consider the possibility of other types of electric-current-induced physical failures. If the shell is being used as a conductor is there going to be sufficient heat rise caused by the combination of electrical resistance and current flow across the mechanical connection to cause physical failure of any of the other connector components, such as strain relief boots, seals, thermoplastic insulation's, etc.? Could there be enough heat rise to cause failure of the electrical wire/cable connection to the connector?

It must be remembered that there are two elements involved in the electrical failure of a connector: the insulation, and the conductor/contacts/connections; in other words, the non- conductive parts and the conductive parts.

Dealing for the moment only with the part of the connector that is meant to disconnect and reconnect (and not with the parts that are attached electrically or otherwise, to the cable/wire; any connector may be broken down into a male-female or hermaphroditic component which is designed to mate with an equivalent part, and thereby pass electricity, and the parts needed to hold the former in alignment. The latter are usually insulators. In many connectors carrying AC signals it is necessary to have the latter parts dimensioned so that the electrical impedance of the connector is the same as that of the wire otherwise there will be a discontinuity and a reflection will occur in the transmission system.

Where the AC electrical impedance is not a consideration we have to deal with losses in or on the electrical insulation. Excessive leakage across the insulation will result in heating in high-power applications, insulation breakdown in high-voltage applications, or signal leakage in multiple-pin control circuits. None of these are acceptable, and the consequences could be destruction of the connector and a fire hazard to consequential damages due to failure of a process-control, alarm, or communications system.

Where AC electrical impedance is a factor, insulation leakage can cause loss of signal strength and or unacceptable modification of the signal caused by line reflections. A good example of the latter is ghosts or detail blurring in cable TV.

Failure of what patent attorneys like to call the "connector means" can range from a simple erratic connection which could be called intermittent, to terminal failure of the contact pair.

The introduction of corrosion products into the gap between the connecting pair o connecting means can also result in problems ranging from rectification effects (most corrosion products can act like crude semiconductors) which can produce strange modulation distortion of the signals or even introduce spurious signals derived from the rectification of whatever RF (conventional RF of even fast rise time) signals ma be present in the environment. Generally this is characterized as excessive sensitive to "electronic smog".

As before, the corrosion products can completely break the contact means or through its increased volume, lock-up the connector so that it cannot be disconnected.

ELECTRICAL FAILURES:

If a mated contact were potted in a clear material, sawn along at right-angles to, the connection plane polished, and examined under a microscope, it would be seen that what we think of as smooth contact surfaces are really almost mountainous, and that as a consequence, the contact area is far from continuous. One of the benefit of gold plating in the days when gold was much less expensive, derived from the fact that gold is soft and malleable. Under the action of making the connection, the gold deformed, producing a much larger total contact area. The plating, being thicker, was much less likely to be porous, and so corrosion was also prevented. In addition, the closely-mated surface prevented the intrusion of oxygen and other contaminants.

At the present cost of gold, where gold is used, it is applied in as thin a "flash" a possible consistent with porosity. Even then special processes are used to try t minimize porosity as will be evident upon reading almost any connector manufacturer's brochures.

Where gold is not used on both surfaces, the question becomes one of the compatibility of the connecting surfaces both with one another and with the intrusion environment. Often when less noble metals than gold are used in a contact pair and combined with sufficiently high contact pressure, they perform with greater reliability than gold to gold, or gold to ? at lower pressure. The key here is to have enough pressure to exclude oxygen and other contaminants.

Stabilant 22 (or its isopropanol diluted form, Stabilant 22A) when used on a con tact needs only be present in a film thick enough to fill the interstices (or gaps) between the contact surfaces. Because of its switching ability, it will become conductive there without becoming conductive between adjacent pains or causing leakage across insulating surfaces.

Now the conductivity of a new connector will not be substantially improved by the Stabilant for the reason that there will probably be sufficient contact already so that any added contact area aided by a material which has a higher volume resistance than the contacting metal will be of minor consequence. However the Stabilant's presence will help to exclude oxygen and corrosive materials from the contacts, and its surfactant action will keep existing contaminants in suspension.

The action of Stabilant on an aging or older contact is somewhat different. Here the contact will not be as good; thus the conductivity of the Stabilant (once switched on) will appreciably lower any contact resistance.

On high current applications, the lowered resistance well may be enough to stop thermal runaway of the contact means, a situation where the heating of a joint causes expansion which by stretching the clamping means beyond their elastic limit results in a reduced contact pressure, increasing the resistance of the contact area, and further increasing the heating. In extreme cases this can literary cause a high current connector to explode.

Because of the "switching threshold effect", Stabilant will not "switch" to a conductive state between adjacent contacts and its "off" resistivity is high enough to prevent signal leakage.

In an environment where it is impossible to guarantee the exclusion of contaminants, silicon grease can be used on the insulation to keep its surface resistance as high as possible. The problem them becomes one of preventing the contamination of the Stabilant by the Silicon, and vice versa.

On low frequency connector applications it is sometimes possible to take a thin sheet of soft silicon rubber (with a Durometer of about 30 to 40 Shore A) and make a washer which is perforated with holes for the male contacts and which will fit inside the connector shell. The material should be thick enough such that when the connector is screwed or clamped together, the silicon will deform and form a water and gas tight seal between the adjacent contacts.

This solution will work only where the connector design allows the silicon washer to be compressed.

Another potential problem in connectors is the area where the wire and or cable is connected to the contact means. Frequently the wire may be of solder or tin plated copper, while the rear of the contact body could be anything from gold-plate, through silver or tin plate, to an as-machined alloy. The introduction of solder itself on a bare copper wire can provide a potential problem of galvanic corrosion while some of the fluxes themselves can cause problems if they wick up into stranded wires. Then too there is the possibility that breakdown products from the cable jacket can cause corrosion of the copper.

Multiple point crimps, made with properly designed tools such that there is sufficient pressure on the conductors are often much more reliable than soldered joints besides having greater consistency. The Stabilants can be used to enhance the operation of such joints.

What procedures can be followed on complete connectors?

Once a connector is assembled, it may be necessary to protect it against the environment by somewhat (in the eyes of the connector manufacturer) less orthodox means. One of the simplest of these is the use of a heat shrinkable polyolefin tubing with an internal low-molecular weight polyolefin (or equivalent) materials that literally melts when the outer tube layer is being shrunk. This provides a much more intimate seal when a length is used that is long enough to stretch from the wire jacket over the connector and on to the wire jacket. A problem with this material is that it looses its elasticity and gets stiff at low temperatures, and if leaks will occur, they will do so when its cold. We have seen this material used with rubber splicing compound (as used on high voltage connections) where a single layer of stretched splicing compound is used over the wire-connector-wire area before the heat shrink tubing is used, The elasticity of the splicing compound under compression is certainly better than that of any of the heat shrinkable materials and the resultant "booted joint" is much less messy to open up.

Another treatment is to use a thick long-fiber-equivalent silicone dielectric grease such as vacuum grease applied in a layer over the connector and wire. This can be used inside heat shrink tubing. Enough should be applied so that the shrinking of the tubing extrudes the excess from the ends of the tubing. A possible problem here is that the grease may also be forced into the connector with degradation of the metal to metal contact. In an attempt to resolve this latter problem I have seen the same treatment used with an external wrapping of kitchen wrap being used to the point that the silicon is covered. Ordinary vinyl tape can be used over this providing the silicone has not got on the surface of the plastic.

Yet another technique is to use one of the low-temperature-melting tool-protection coating material such as the buterates. These are an oil bearing plastic material normally used in the tool-room to protect sharpened milling cutters against damage. The material melts easily and connectors can be dipped into the liquefied butyrate. It is not easy to apply in the field, but it can be readily cut and is easy to strip away from the connector.

All of these solutions are, of course, designed to exclude the salt and moisture from the connector and a choice of which treatment to use will be based on the location of the connectors, the ease of application of the treatment, and the life of the materials used. Consideration must also be given to possible degradation of heat shrink materials themselves by ultraviolet, ozone, or chemical contaminants.

In what forms is Stabilant available?

The Stabilants come in different forms. The basic material or concentrate is called Stabilant 22, while the isopropanol diluted form is designated Stabilant 22A. This is a 4:1 isopropanol dilution (by volume) and is much easier to apply. When used a normal room temperatures or higher, the isopropanol will evaporate after the application, leaving a thin film of the concentrate in place. In some applications such as socketed IC's it is not even necessary to unplug the IC to treat the connection. The dilute form should be used for treating existing crimp-type joints between multiple stranded wire and the contact.

Where isopropanol is not allowed, consider using Stabilant 22E with a diluant of ethanol!

What are the names of some of the materials that can be used to exclude water?

Silicone greases are manufactured by several companies including Dow Corning and General Electric Silicones Division. Besides the usual silicone dielectric greases, which are available from many manufacturers there is a much stiffer silicone grease called High-Vacuum grease which is somewhat easier to handle as an external moisture barrier due to its higher viscosity.

If there is a restriction banning silicones from use we have been told that Apiezion Grease type T and the more rubbery Apiezion- type N grease (both generally used in laboratory glassware applications) have had some success.

Heat Shrinkable tubing is manufactured by such companies as Alpha. The surface irradiated type with the soft inner core is their type FIT-300. Their standard shrinkable polyolefin tubing is type FIT-221.

Revision 2


Stabilants are a product of Dayton Wright research & development and are made in Canada

NSCM/Cage Code - NATO Supply Code 38948

15 mL of S22A has NATO Part # 5999-21-900-6937


The Stabilants are patented in Canada - 1987; US Patent number 4696832. World-wide patents pending. Because the patents cover contacts treated with the material, a Point-of-sale License is granted with each sale of the material.

MATERIAL SAFETY DATA SHEETS ARE AVAILABLE ON REQUEST


Stabilant, Stabilant 22, and product type variations thereof are Trade Marks of D.W. Electrochemicals Ltd.

Copyright 2003 - D.W. Electrochemicals Ltd. This note may be reproduced or copied, provided its content is not altered. The term "contact enhancer", 1983 Wright Electroacoustics.


NOTICE: This Application Note is based on customer-supplied information, and D.W. Electrochemicals is publishing it for information purposes only. In the event of a conflict between the instructions supplied by the manufacturer of the equipment on which the Stabilant material was used, and the service procedure employed by our customer, we recommend that the manufacturer be contacted to make sure that warranties will not be voided by the procedures.

While to our knowledge the information is accurate, prospective users of the material should determine the suitability of the Stabilant materials for their application by running their own tests. Neither D.W. Electrochemicals Ltd., their distributors, or their dealers assume any responsibility or liability for damages to equipment and/or any consequent damages, howsoever caused, based on the use of this information.

Stabilant, Stabilant 22, and product type variations thereof are Trade Marks of D.W Electrochemicals Ltd.

 Contact Us 
Shopping Cart more
  View detailed Shopping Cart contents.0 items
Stabilant
Stabilant 22 Contact Enhancer

Stabilant 22 Contact Enhancer

We carry the complete line of Stabilant products. Looking for something not listed here? Please contact us.
Stabilant 22
APPLICATION NOTES
1. Electronic Equipment
2. Computer cards
3. Schadow switches
4. Mic connectors
5. RTS & Dual plug patch bays
6. Biomedical Electronics
7. Computing & Peripherals
8. Cable TV
9. Robotics
10. Environmental Impact
11. Recording studios
12. Broadcast equipment
13. Mobile Radio
14. Educational computing
15. Stereo systems
16. Aid to IC insertion
17. Navigational equipment
18. Card edge conn. problems
19. Complex process control
20. Automotive service
21. Gold plating/solder alloy
22. Very high humidity
23. High current thermal runaway
24. Car stereo systems
25. Plastic element pots.
26. Farm machinery & trucks
27. Model & hobby
28. RF case seals
29. Outdoor environments
30. Computer crashes
31. Relays & switches
32. Silicone problems
33. Tin-plated contacts
34. Solder flux & resin residue
35. Post application color tinting
36. Aircraft connectors w/ flurosilicones
37. Avoiding unsafe solvents
38. S22 R&D Design Goals
39. Stabilant use on PLCC's
40. Sensor problem solution
41. Repair of flood damage
42. Marine electrical & electronics
43. All Cameras & Video Equipment
44. SCSI removable SCA drives, caddies & connections
45. Home Theater & Computer Connectors

Some of these application notes are repetitive of material in other application notes. We realize this. But some were written as a reference to a contact problem in a particular field or application.

NOTICE: This data has been supplied for information purposes only. While to our knowledge it is accurate, users should determine the suitability of the material for their application by running their own tests. Neither R.A.L. Audio Services, D.W. Electrochemicals Ltd., their distributors, or their dealers assume any responsibility or liability for damages to equipment and/or consequent damages, howsoever caused, based on the use of this information.
Product Categories
 Audio Services
 Used Equipment
 Stabilant 22
 Accessories - Misc.
 Acoustical
        Treatments

 Bass Management
 Cable / Wire /
        Connectors

 Cases / Racks /
              Covers

 Consoles & Mixers
 Crossovers
 Digital Audio
 Direct Boxes / DI's
 DJ Stuff
 Guitars / Basses
 Guitar / Bass
        Accessories

 Headphones
 Headphone Amplifiers
 Microphones
 Microphone
              Preamplifiers

 Microphone
        Accessories

 Power Amplifiers
 Power Supplies /
              Conditioners

 Re-Amplifiers
 Replacement Parts
 Rigging / Safety
              Cables

 Signal Distribution
 Signal Processors
 Speakers / Monitors
 Speaker Management
 Splitters &
              Isolators

 Stage Lighting /
              Trusses

 Studio Lighting
 Sync's / Clocks /
              R.C.s

 Tape Recorders
 Test Equipment
 Wireless
View All Specials
View Latest Additions
View All Products By:
Category or Manufacturer
Stabilant 22
REVIEWS
Over the years, Stabilant 22 has been highly parsed in publications that target a wide range of electronics applications including:
* Andrew Marshall's Audio Ideas Guide
* BYTE Magazine (7 articles)
* Windows Magazine
* Q.S.T. Amateur Radio
* Model Railroads (2 articles)
* Motor Magazine
Stabilant 22
TECHNICAL NOTES
1. MSDS - Stabilant 22
2. General Information
4. MSDS - Stabilant 22A
5. MSDS - Stabilant 22E
9. MSDS - Stabilant 22L
20. Military Applications
21. Elastomer Compatibility
22. Effectiveness of Stabilants
24. Connector Harmonic Distortion
39. Signal rise time

There are gaps in the sequence numbers below because some Technical Note s were written by the manufacturer for specific companies and are confidential.

NOTICE: This data has been supplied for information purposes only. While to our knowledge it is accurate, users should determine the suitability of the material for their application by running their own tests. Neither R.A.L. Audio Services, D.W. Electrochemicals Ltd., their distributors, or their dealers assume any responsibility or liability for damages to equipment and/or consequent damages, howsoever caused, based on the use of this information.
Stabilant
Stabilant 22 Contact Enhancer

Stabilant 22 Contact Enhancer

We carry the complete line of Stabilant products. Looking for something not listed here? Please contact us.

Get Adobe Reader All prices in US dollars.
Sales tax will be added to all purchases delivered in California.
Prices, products, and specifications subject to change without notice.
All trademarks and registered trademarks are owned by their respective companies.
We accept Visa, Mastercard, Discover and American Express