R.A.L. Audio Services
    Shop by Brand (click here) What Goes In... Comes Out!
What Goes In... Comes Out!
 Reset 
 
Search for Stabilant products. Advanced Search

Call us Toll Free at 866-455-3997

 Home  Recording  Rental  Modifications  Installation  Leasing  Policies  Contact  About  Login  View Cart  Checkout  

Stabilant 22 Contact Enhancer Technical Notes

Tech. Note 1 - Material Safety Data Sheet - Stabilant 22

MATERIAL SAFETY DATA SHEET -STABILANT 22 - EXPIRES 01/02/2015

Manufactured by: D.W. ELECTROCHEMICALS LTD.

  • 3-97 Newkirk Road North, (Unit 3)
  • Richmond Hill, Ontario L4C 3G4
  • CANADA
  • Phone: (905) 508-7500
  • Fax: (905) 508-7502
NO HEALTH HAZARD KNOWN - NO FIRE HAZARD 

DESIGNATION

  • Name: Stabilant 22 (No synonyms)
  • Use: Electrical contact enhancer
Chemical Name & Identity:
  • 100% [No Fire or Health Hazard] - falls under 9003-11-6 (a ModifiedPolyoxypropylene-Polyoxyethylene Block Polymer of the Polyglycol family.
HAZARDOUS INGREDIENTS
  • Hazardous Ingredients: (EPA & TSCA) - None (WHMIS) - None
PHYSICAL DATA
  • Physical State: Liquid
  • Appearance: Cloudy to clear liquid
  • Odor: Faint Musty odor
  • Odor Threshold: No Data
  • Melting Point: Pour point 16' Celsius
  • Boiling Point: None
  • Specific Gravity: 1.05
  • Density: 1.05 gms/ml
  • Decomposition Temp: >210° C
  • Solubility in water: 100 grams per liter
  • Vapor Pressure: No Tests Run
  • Vapor Density: No Tests Run
  • Vapor Pressure(mm): No Tests Run
  • Evaporation Rate: No Tests Run
  • Index of refraction:1.454 at 25° deg. Celsius
  • Coefficient of Water/oil distribution: No Tests Run
  • pH: 6.1 to 7.5 @ 1 0 g/l
  • Total Organic Carbon (TOC): 28%
FIRE & EXPLOSION HAZARDS
  • Flammability: Will support combustion on decomposition - e.g.. materialtemperature must have been raised above 200' Celsius
  • Lower Explosion Limit (% by Volume): No Tests Run
  • Flash Point: 200° Celsius
  • Method: coc
  • Hazardous Combustion Products: None known
  • Extinguishing Media: Water fog, C02, Foam, Dry Chemical
  • Special Procedures: Self Contained Breathing Apparatus should beused when fighting a fire in a confined area or when exposed to contaminationproducts.
  • Auto-ignition temperature: No Tests Run
  • Explosion Data:- Sensitivity to impact: None known
  • Sensitivity to Static Discharge: No Tests Run
  • Unusual Fire & Explosion Hazards: Improperly Disposed of Stabilantsoaked combustible materials might be subject to spontaneous combustion.
  • Dangerous Goods Class: None
HEALTH EFFECTS DATA
  • Routes of Entry: Not to be taken orally, no prolonged skin or eyeirritation noted on prolonged exposure
  • LD50: 5 grams/kilogram (Oral)
  • Tested on: Rats
  • Skin Overexposure effects: Prolonged skin or eye contact may causelight temporary irritation.
  • Skin Irritation: Limited Tests indicate no significant long termirritation
  • Eye Irritation: Limited Tests indicate no significant long termirritation.
  • Inhalation Acute: Very low vapor pressure suggests that this wouldnot be applicable.
  • Inhalation Chronic: Very low vapor pressure suggests that this wouldnot be applicable
  • Oral Ingestion: Oral ingestion of small amounts will cause diarrhea.Oral Ingestion of large amounts could cause systemic collapse.
  • Effects of Acute Exposure: Oral - see above; Skin or eye, Limitedtests indicate no significant long term irritation
  • Effects of Chronic Exposure: Oral - see above; Skin or eye, Limitedtests indicate no significant long term irritation.
  • Exposure Limits: No Tests Run - Very low vapor pressure combinedwith the very low toxicity and the small surface areas of the materialwhen applied to contacts suggests that for practical purposes it wouldbe virtually impossible to reach an airborne concentration that would beinjurious. Limited testing on skin exposure indicate no significant longterm irritation or sensitization. We suggest a precautionary washing ofthe exposed areas with soap and water.
  • Sensitization to Material: Limited Tests indicate no sensitizationeffects.
  • Carcinogenicity: None Known
  • Reproductive Effects: No Tests Run.
  • Tetratogenicity: No Tests Run.
  • Mutagenicity: No Tests Run.
  • Synergistic Materials: None Known.
REACTIVITY DATA
  • Stability: Stable
  • Conditions to avoid: Excessive Temperatures
  • Incompatibility: None known
  • Hazardous Decomposition Products: None known
  • Hazardous Polymerization or Reactivity: Will not occur
ECOLOGICAL DATA
  • Biodegradability: No tests run - No data
  • Fish Toxicity: At concentrations of up to 5 ppm. no toxic reactionswere noted
  • Bacterial Inhibition in Influent: No Data
ENGINEERING CONTROLS
  • Bulk handling Observe physical safety procedures commensurate withthe size of the container involved
  • Dilution: Precautions should be taken to be sure that diluted materialsare properly labeled as to the diluant used.
SPECIAL PROTECTION INFORMATION
  • Ventilation: General mechanical ventilation is adequate
  • Respiratory Protection: Use an approved respirator if exposed tomists or aerosols
  • Protective Gloves: Rubber, Neoprene or Plastic when handling bulkamounts
  • Eye Protection: Goggles or Face shield when handling bulk amounts.
  • Footwear: Non slip when handling bulk amounts
  • Clothing: Apron when handling bulk amounts
  • Other: Not required
OTHER REGULATORY INFORMATION
  • United States: The materials in this product have been reviewedand are not reportable under SARA title III
  • Customs: The material is classified as Semiconductors, Other - underHarmonized # 8541.50.00.80
SPECIAL STORAGE PRECAUTIONS
  • Handling & Storage Procedures: Avoid eye contact and prolongedskin contact. Store in a cool dry location.
SPECIAL SHIPPING INFORMATION
  • Shipping Name: Stabilant 22 - Semiconductor: Other
  • PIN (Product ID#) None
  • Packing Group Class: Non-toxic
  • Special Provision: None
  • Subsidiary Class: None
  • Schedule XII: Not applicable (Harmonized Control Number - 8541.50.00.80
FIRST AID - EMERGENCY
  • Fire: No special requirements known
  • Eyes: Flush immediately with flowing water for a period of at least10 minutes and consult a physician.
  • Skin: Wash with soap and water. Remove and launder contaminatedclothing before re-use. Consult a physician If irritation develops at siteof exposure.
  • Ingestion: Induce vomiting and consult a physician.
  • Inhalation: If the material is sprayed in large quantities, excessiveaerosol inhalation will cause irritation, congestion, and act as an expectorant.Consult a physician
HOUSEKEEPING PROCEDURES
  • Clean-up of Leaks & Spills: As spilled material is quite slipperyit should be covered with absorbent anti-skid material and cleaned up immediately.
  • Disposal of Waste: This product is not a hazardous waste when discardedas defined in 40CFR261.337. This product is not a halognated solvent whenspent as defined in 40CFR261.317. This product may be incinerated togetherwith domestic waste so long as local regulations permit incineration.
  • Halogen content: 0 ppm (µg/g
  • Sulfur content: 0 ppm (µg/g)
  • No chelating agent action.
OTHER DATA (Excluded from waiver at end of MSDS)

Stabilant 22 Contact Enhancer Technical NotesHeavy Metals: D.W. Electrochemicals Ltd. has a policy of not allowingany intentional addition of any heavy metals, such as lead, cadmium, mercury,or hexavalent chromium, or their compounds, to be used in inks or in thelabels on our packaging and requires the total concentration of these materials,if present, to be so at a level of less than 100 parts per million andwe so certify.

  • RoHS Legislation Artical 4(1) pertaining to Heavy Metals in Stabilantsand other prohibited components: D.W. Electrochemicals Ltd. has a policyof not allowing any addition of any heavy metals, such as lead, cadmium,mercury, or hexavalent chromium, or their compounds, to be used in theStabilants and requires the total concentration of these materials, ifpresent, to be so at a level of less than 100 parts per million and weso certify.
  • Ozone Depleting Chemicals: Because of our corporate opposition tothe use of ODC's either in the manufacture of, or as an inclusion in anyof our products, D.W. Electrochemicals Ltd. has consistently refused toprovide any of our products in aerosol spray packaging and/or to supplyany of our materials diluted with any Class 1 ODC, and we so certify.
  • PCB's: We certify that this material has been subjected to testscapable of detecting PCB's to a level of less than 2 parts per millionand no PCB's have been found.
  • Packaging: New standards are in place in an attempt to reduce theamount of plastics, tape and/or adhesives used and to ensure that our packagingmay be reused or recycled.
MSDS PREPARATION DATA & EMERGENCY PHONE NUMBER
  • Prepared By: Wm Wright
  • Department: Engineering
  • Preparation Date: January 2nd, 2005
  • Current Revision: Revision 26-Updated, also for inclusion inweb site
  • Emergency Phone: (905) 508-7500
  • Emergency Contact: Wm Wright

Patented Canada 1987, Us Patent 4696832. Others Pending.

©1997 D. W. Electrochemicals Ltd. This note may bereproduced or copied, provided its content is not altered. The term "contactenhancer" © 1983 Wright Electroacoustics.


NATO/CAGE Supplier code #38948

15 mL Stabilant 22 has NATO Stock Number 5999-21-909-9981


D.W. Electrochemicals Ltd. urges each customer or recipientof this MSDS to study it carefully to become aware of/and understand thehazards associated with the product. The reader should consider consultingreference works or individuals who are experts in ventilation, toxicologyor fire prevention, as necessary or appropriate to use and understand thedata contained in this MSDS.

To promote safe use and handling of this product, eachcustomer or recipient should (1) notify employees, agents, contractorsand others who may use this material, of the information in this MSDS andany other information regarding hazards or safety, (2) Furnish this sameinformation to each customer for the product, and (3) request customersto notify their employees, customers, and other users of the product ofthis information.

The information and recommendations contained herein arebased on data believed to be correct, however no guarantee or warrantyof any kind, expressed or implied, is made with respect to informationand recommendations contained herein except where certified..

Revision 26

 Contact Us 
Shopping Cart more
1 x Stabilant 22S 50mL Bottle
1 x Stabilant 22 15mL
1 x Stabilant 22 100mL
1 x Stabilant 22 5mL
1 x Stabilant 22S 100mL Bottle
1 x Stabilant 22 50mL
  View detailed Shopping Cart contents.$1,216.75
Stabilant
Stabilant 22 Contact Enhancer

Stabilant 22 Contact Enhancer

We carry the complete line of Stabilant products. Looking for something not listed here? Please contact us.
Stabilant 22
APPLICATION NOTES
1. Electronic Equipment
2. Computer cards
3. Schadow switches
4. Mic connectors
5. RTS & Dual plug patch bays
6. Biomedical Electronics
7. Computing & Peripherals
8. Cable TV
9. Robotics
10. Environmental Impact
11. Recording studios
12. Broadcast equipment
13. Mobile Radio
14. Educational computing
15. Stereo systems
16. Aid to IC insertion
17. Navigational equipment
18. Card edge conn. problems
19. Complex process control
20. Automotive service
21. Gold plating/solder alloy
22. Very high humidity
23. High current thermal runaway
24. Car stereo systems
25. Plastic element pots.
26. Farm machinery & trucks
27. Model & hobby
28. RF case seals
29. Outdoor environments
30. Computer crashes
31. Relays & switches
32. Silicone problems
33. Tin-plated contacts
34. Solder flux & resin residue
35. Post application color tinting
36. Aircraft connectors w/ flurosilicones
37. Avoiding unsafe solvents
38. S22 R&D Design Goals
39. Stabilant use on PLCC's
40. Sensor problem solution
41. Repair of flood damage
42. Marine electrical & electronics
43. All Cameras & Video Equipment
44. SCSI removable SCA drives, caddies & connections
45. Home Theater & Computer Connectors

Some of these application notes are repetitive of material in other application notes. We realize this. But some were written as a reference to a contact problem in a particular field or application.

NOTICE: This data has been supplied for information purposes only. While to our knowledge it is accurate, users should determine the suitability of the material for their application by running their own tests. Neither R.A.L. Audio Services, D.W. Electrochemicals Ltd., their distributors, or their dealers assume any responsibility or liability for damages to equipment and/or consequent damages, howsoever caused, based on the use of this information.
Product Categories
 Audio Services
 Used Equipment
 Stabilant 22
 Accessories - Misc.
 Acoustical
        Treatments

 Bass Management
 Cable / Wire /
        Connectors

 Cases / Racks /
              Covers

 Consoles & Mixers
 Crossovers
 Digital Audio
 Direct Boxes / DI's
 DJ Stuff
 Guitars / Basses
 Guitar / Bass
        Accessories

 Headphones
 Headphone Amplifiers
 Microphones
 Microphone
              Preamplifiers

 Microphone
        Accessories

 Power Amplifiers
 Power Supplies /
              Conditioners

 Re-Amplifiers
 Replacement Parts
 Rigging / Safety
              Cables

 Signal Distribution
 Signal Processors
 Speakers / Monitors
 Speaker Management
 Splitters &
              Isolators

 Stage Lighting /
              Trusses

 Studio Lighting
 Sync's / Clocks /
              R.C.s

 Tape Recorders
 Test Equipment
 Wireless
View All Specials
View Latest Additions
View All Products By:
Category or Manufacturer
Stabilant 22
REVIEWS
Over the years, Stabilant 22 has been highly parsed in publications that target a wide range of electronics applications including:
* Andrew Marshall's Audio Ideas Guide
* BYTE Magazine (7 articles)
* Windows Magazine
* Q.S.T. Amateur Radio
* Model Railroads (2 articles)
* Motor Magazine
Stabilant 22
TECHNICAL NOTES
1. MSDS - Stabilant 22
2. General Information
4. MSDS - Stabilant 22A
5. MSDS - Stabilant 22E
9. MSDS - Stabilant 22L
20. Military Applications
21. Elastomer Compatibility
22. Effectiveness of Stabilants
24. Connector Harmonic Distortion
39. Signal rise time

There are gaps in the sequence numbers below because some Technical Note s were written by the manufacturer for specific companies and are confidential.

NOTICE: This data has been supplied for information purposes only. While to our knowledge it is accurate, users should determine the suitability of the material for their application by running their own tests. Neither R.A.L. Audio Services, D.W. Electrochemicals Ltd., their distributors, or their dealers assume any responsibility or liability for damages to equipment and/or consequent damages, howsoever caused, based on the use of this information.
Stabilant
Stabilant 22 Contact Enhancer

Stabilant 22 Contact Enhancer

We carry the complete line of Stabilant products. Looking for something not listed here? Please contact us.

Get Adobe Reader All prices in US dollars.
Sales tax will be added to all purchases delivered in California.
Prices, products, and specifications subject to change without notice.
All trademarks and registered trademarks are owned by their respective companies.
We accept Visa, Mastercard, Discover and American Express